Denver Water Contaminants Detected
Location
Denver, Colorado
Serves
1,287,000
Source
Surface Water
Data
2013-2024
Bromodichloromethane
Potential Effect: Cancer
This Utility: 8.02 ppb
No Legal Limit
134x
EWG’s Health Guideline: 0.06 ppb
Chloroform
Potential Effect: Cancer
This Utility: 18.9 ppb
No Legal Limit
47x
EWG’s Health Guideline: 0.4 ppb
Dibromoacetic acid
Potential Effect:
This Utility: 0.119 ppb
No Legal Limit
4x
EWG’s Health Guideline: 0.03 ppb
Dibromochloromethane
Potential Effect: Cancer
This Utility: 1.90 ppb
No Legal Limit
19x
EWG’s Health Guideline: 0.1 ppb
Dichloroacetic acid
Potential Effect: Cancer
This Utility: 10.1 ppb
No Legal Limit
51x
EWG’s Health Guideline: 0.2 ppb
Haloacetic acids (HAA5)
Potential Effect: Cancer
This Utility: 16.6 ppb
Legal Limit: 60 ppb
166x
EWG’s Health Guideline: 0.1 ppb
Haloacetic acids (HAA9)
Potential Effect: Cancer
This Utility: 14.7 ppb
No Legal Limit
246x
EWG’s Health Guideline: 0.06 ppb
Radium, combined (-226 and -228)
Potential Effect: Cancer
This Utility: 0.74 pCi/L
5 pCi/L
15x
EWG’s Health Guideline: 0.05 pCi/L
Total trihalomethanes (TTHMs)
Potential Effect: Cancer
This Utility: 28.9 ppb
Legal Limit: 80 ppb
192x
EWG’s Health Guideline: 0.15 ppb
Trichloroacetic acid
Potential Effect: Cancer
This Utility: 6.33 ppb
No Legal Limit
63x
EWG’s Health Guideline: 0.1 ppb
| CONTAMINANTS ABOVE HEALTH GUIDELINES | activated carbon | reverse osmosis | ion exchange |
|---|---|---|---|
| Bromodichloromethane | yes | yes | no |
| Chloroform | yes | yes | no |
| Dibromoacetic acid | yes | yes | no |
| Dibromochloromethane | yes | yes | no |
| Dichloroacetic acid | yes | yes | no |
| Haloacetic acids (HAA5) | yes | yes | no |
| Haloacetic acids (HAA9) | yes | yes | no |
| Radium, combined (-226 & -228) | no | yes | yes |
| Total trihalomethanes (TTHMs) | yes | yes | no |
| Trichloroacetic acid | yes | yes | no |
| OTHER CONTAMINANTS DETECTED | activated carbon | reverse osmosis | ion exchange |
|---|---|---|---|
| 4-Androstene-3,17-dione | yes | yes | no |
| Barium | no | yes | yes |
| Bromoform | yes | yes | no |
| Cadmium | yes | yes | yes |
| Chlorodifluoromethane | no | no | |
| Chromium (hexavalent) | no | yes | yes |
| Chromium (total) | no | yes | yes |
| Fluoride | no | yes | no |
| Lithium | no | yes | yes |
| Manganese | no | no | yes |
| Molybdenum | no | yes | yes |
| Nitrate | no | yes | yes |
| Nitrate & nitrite | no | yes | yes |
| Strontium | no | yes | yes |
| Uranium, combined (pCi/L) | no | yes | yes |
| Vanadium | no | no | yes |